Heat Pump Flow Temperature Explained: Lower Temps, Lower Bills

Lower flow temperatures make heat pumps cheaper to run. Learn what flow temperature is, what to aim for, and how to lower it one degree at a time.

By Galactic News Editorial · Published 2026-11-27T02:13:43+00:00 · Updated 2026-11-27T02:13:43+00:00

Heat pump flow temperature explained: lower temps, lower bills

Heat Pump Flow Temperature Explained: Lower Temps, Lower Bills

Heat pump flow temperature is the temperature of the water leaving your heat pump on its way to your radiators or underfloor heating. Lower it, and the heat pump works less hard for each unit of heat it delivers. That shows up directly in your electricity bill. The skill is finding the lowest temperature that still keeps every room warm. This guide explains what flow temperature is, why it matters, and how to lower it in small, safe steps.

What Heat Pump Flow Temperature Means

Heat pump flow temperature is the temperature of the water as it leaves the heat pump and enters the heating circuit. It is not the room temperature on your thermostat. It is the temperature of the water doing the work.

Gas boilers usually send water out at 60 to 80 degrees. Heat pumps work best at much lower temperatures, typically 35 to 55 degrees. That is the core difference between the two systems. A boiler makes heat by burning fuel, so hot water costs it little extra. A heat pump moves heat from cold outdoor air into your home, and the bigger the temperature lift, the harder the compressor works.

Two numbers matter. Design flow temperature is the water temperature the system is built to reach on the coldest design day. Day-to-day flow temperature is what the system actually runs at, and it should fall on milder days. A system designed for 45 degrees on the coldest day may run at 35 degrees for much of the winter.

Why a Lower Heat Pump Flow Temperature Cuts Bills

A heat pump's efficiency is measured by its coefficient of performance, or COP. A COP of 3 means three units of heat for each unit of electricity. The COP falls as the temperature lift rises. Every degree you cut from the flow temperature lifts the COP on every heating hour.

Real homes back this up. The Electrification of Heat trial, run by Energy Systems Catapult across 742 UK homes, found a median seasonal performance factor of 2.80 for air source heat pumps. Homes with lower average flow temperatures performed better. Design and controls, not the brand of heat pump, explained most of the gap between homes.

The money follows the same pattern. One worked example at the Ofgem October to December 2026 electricity rate of 26.32p per kWh puts a home needing 10,000 kWh of heat a year at about £940 with a seasonal efficiency of 2.8, and about £752 at 3.5. That is roughly £190 a year from settings and radiators alone.

What Flow Temperature Should You Aim For?

There is no single correct number. The right figure depends on your home, your radiators, and your climate. These are typical ranges for cold days:

EmitterTypical flow temperatureNotes
Underfloor heating30 to 35°CThe lowest setting, because the whole floor gives off heat
Large or low-temperature radiators40 to 45°CThe target for most well-sized radiator systems
Standard radiators sized for a boiler50 to 55°CWorks, but at lower efficiency; larger radiators may pay for themselves
Hot water cylinder50 to 55°CKept separate from space heating; do not mix the two settings

Your installer should have set a heating curve when the system was fitted. That curve, also called weather compensation, raises the flow temperature when it gets colder outside and lowers it when the weather is mild. The Energy Saving Trust says this should normally be set by the installer, and that the system should vary the flow temperature with the season on its own.

How to Lower Your Heat Pump Flow Temperature in 5 Steps

  1. Find the heating curve setting on your controller and note the current value, so you can return to it.
  2. Turn the curve down by one degree.
  3. Wait at least a day, and longer in cold weather, before judging the result. Radiators at low temperatures warm rooms slowly.
  4. Repeat the one-degree drop until a room feels too cool.
  5. Turn it back up by one degree and leave it there. That is your lowest comfortable setting.

This is the method the Energy Saving Trust recommends for lowering your heat pump flow temperature. It is slow on purpose. A one-degree change is small enough to test safely, and the test only works if you give the house time to settle. Never drop the setting by five degrees at once and hope for the best.

Keep It Running: Set-Back Beats Switching Off

Heat pumps run best for long periods at a low flow temperature. The Energy Saving Trust recommends keeping the heating on and dropping the room temperature by a few degrees overnight or while you are out, rather than switching the system off. This is called set-back.

Switching off looks like saving, but reheating a cold house forces the heat pump to a high flow temperature at the coldest time of day. That is the least efficient way to run it. A small set-back of one or two degrees holds the house warm enough that the morning warm-up stays gentle.

One exception: do not let the system heat hot water overnight when outdoor temperatures are at their lowest, unless you are on a time-of-use tariff that makes overnight electricity cheap.

When a Low Flow Temperature Does Not Work

Lower is not automatically better. If rooms stay cold at 40 degrees, the radiators are too small for the heat loss, not the heat pump. Larger radiators give out more heat from the same wall space. A double or triple-panel radiator often fixes one cold room without touching the rest of the system.

Hot water is a separate job. Keep the cylinder at its own setting, usually 50 to 55 degrees, and let the heating circuit run cooler. Legionella control cycles, which heat the cylinder higher on a schedule, should stay as the installer set them.

If your design flow temperature is above 55 degrees, ask your installer about the alternative. Under the MCS design standard, a design proposing more than 55 degrees should come with a lower-temperature alternative, so you can see the efficiency and cost difference before you choose.

Bottom Line

Heat pump flow temperature is the single biggest lever on your heating bill. Aim for the lowest temperature that keeps every room warm, usually 35 degrees for underfloor heating and 40 to 45 degrees for radiators. Lower the heating curve one degree at a time, keep the system running with a small set-back, and let weather compensation do the daily work. If rooms stay cold, the radiators need attention, not the heat pump.