How to Size a Solar Battery: Capacity, Output and Backup Hours

Sizing a solar battery comes down to three numbers: daily energy use, peak power, and backup hours. This guide walks through the math with worked examples.

By Galactic News Editorial · Published 2026-11-17T13:47:13+00:00 · Updated 2026-11-17T13:47:13+00:00

How to size a solar battery for home backup power

How to Size a Solar Battery: Capacity, Output and Backup Hours

Sizing a solar battery comes down to three numbers. First, how much energy your home uses each day. Second, how much power your appliances draw at once. Third, how many hours of backup you want. Get those three right, and the battery size follows from simple math. This guide walks through each step, with worked examples you can repeat for your own home.

How to Size a Solar Battery in Five Steps

Work through these steps in order. Each one feeds the next.

  1. List your essential loads. Write down every appliance the battery must run during an outage. Note each one's wattage and how many hours per day it runs.
  2. Add up daily energy use. Multiply watts by hours for each load, then add the results. This gives your daily energy need in watt-hours.
  3. Pick your backup duration. Decide how many hours or days the battery must carry those loads without grid power or sunshine.
  4. Apply depth of discharge and efficiency. Divide by the battery's usable share and round-trip efficiency to get the nameplate capacity to buy.
  5. Check power output. Add up the watts of everything that may run at the same time, including motor start-up surges. The battery's continuous output must cover that peak.

Skip step five and you can buy a battery with plenty of energy that still cannot start your well pump or air conditioner. Capacity and output are different jobs.

Capacity vs Power Output: The Two Numbers That Matter

Capacity is measured in kilowatt-hours (kWh). It tells you how much energy the battery stores. Power output is measured in kilowatts (kW). It tells you how much energy the battery can deliver at any one moment.

A useful comparison: capacity is the size of the fuel tank, and output is the size of the engine. A big tank with a small engine runs a long time but cannot power much at once.

Real products show the gap clearly. A Tesla Powerwall 3 stores 13.5 kWh of usable energy and delivers up to 11.5 kW of continuous power. An Enphase IQ Battery 5P stores 5.0 kWh per unit and delivers 3.84 kW. A Franklin aPower 2 stores 15 kWh and delivers 10 kW. Two batteries with similar capacity can have very different output.

Check both numbers on the datasheet before you buy. The headline number is usually capacity. The number that decides whether your air conditioner starts is output.

The Sizing Formula, Worked Through

The core formula is simple:

Required nameplate kWh = (daily kWh x days of backup) / (depth of discharge x efficiency)

Depth of discharge is the share of the battery you can safely use. Efficiency covers the energy lost on the round trip through the inverter and battery. Lithium systems typically run at 90 to 95 percent round-trip efficiency. Lead-acid systems run closer to 80 to 85 percent.

Here is a worked example. A home needs 10 kWh per day for its essential loads. It wants one full day of backup. The battery is lithium iron phosphate with 80 percent usable depth of discharge and 90 percent efficiency.

10 / (0.80 x 0.90) = 13.9 kWh of nameplate capacity. In practice, that means one 13.5 kWh unit is just short, and two units give comfortable headroom. Or a modular system can be sized closer to the target.

For context, the average American home uses about 29 to 30 kWh of electricity per day. Most households do not back up everything. Essential loads only, such as a fridge, lights, internet, and a sump pump, often total 6 to 10 kWh per day. Full-home backup usually needs far more.

How Many Backup Hours Will Your Battery Cover?

Backup hours depend on how much you run at once. Divide usable capacity by your average load to get a rough answer.

Usable capacityAverage loadBackup time
10 kWh0.5 kW (fridge, lights, internet)About 20 hours
13.5 kWh0.5 kW (fridge, lights, internet)About 27 hours
13.5 kWh1.5 kW (essentials plus a small air conditioner)About 9 hours
27 kWh1.5 kW (essentials plus a small air conditioner)About 18 hours
27 kWh3 kW (whole home, modest use)About 9 hours

These are planning estimates. Real backup time varies with temperature, battery age, and how the loads cycle on and off. A fridge compressor runs in bursts, not constantly. An air conditioner is the biggest single load in most homes.

One Powerwall 3 can keep essentials such as a fridge, lights, internet, and sump pump running for roughly 24 to 48 hours. Backing up a whole home, including air conditioning, a dryer, and an EV charger, usually takes two or three units.

Battery Chemistry Changes the Math

Not all batteries let you use their full rated capacity. The chemistry sets the safe depth of discharge, and that changes how much you must buy.

Battery typeUsable depth of dischargeRound-trip efficiencyTypical cycle life
Lithium iron phosphate (LFP)80 to 90 percent90 to 95 percent4,000 to 6,000+ cycles
Other lithium-ion80 to 90 percent90 to 95 percentThousands of cycles
Flooded lead-acidAbout 50 percent75 to 85 percentShorter, depends on use
Sealed lead-acid (AGM)About 50 percent80 to 85 percentShorter, depends on use

The practical effect is large. A 10 kWh LFP battery at 80 percent depth of discharge delivers about 8 kWh of usable energy. A 10 kWh lead-acid bank at 50 percent delivers about 5 kWh. To get the same usable energy from lead-acid, you need roughly double the nameplate capacity.

Temperature matters too. Cold weather raises internal resistance and cuts discharge capacity. Lithium batteries generally should not charge below freezing unless the unit has a heater. Check the datasheet for the operating temperature range of any battery you consider.

Common Sizing Mistakes to Avoid

Sizing for the whole house when you only need essentials. Whole-home backup sounds reassuring. It often doubles or triples the cost. Most homes are better served by backing up a short list of critical circuits.

Forgetting motor start-up surges. Motors draw several times their running watts for a second or two at start-up. A well pump or air conditioner compressor can trip a battery that handles the running load easily. Check the locked-rotor amps rating on the battery datasheet.

Ignoring the recharge window. A battery that drains in one cloudy day needs enough solar to refill it the next day. Size the solar array and the battery together, not separately.

Buying nameplate capacity instead of usable capacity. Always compare batteries on usable kWh, not the headline number. Two 10 kWh batteries can deliver very different usable energy.

Leaving no reserve. Keep a small reserve, often 10 to 20 percent, for emergencies. A battery drained to zero every night ages faster and leaves nothing for an unexpected outage.

What About the Federal Tax Credit?

The federal residential clean energy credit under Section 25D is not available for expenditures made after December 31, 2025. That change came from legislation enacted in July 2025. A battery bought and installed now does not qualify for that credit. State and utility incentives may still apply, so check your local programs before you budget.

Bottom Line

Size a solar battery in this order: list essential loads, add up daily energy use, choose backup duration, apply depth of discharge and efficiency, then check power output against peak loads. Most homes find that 10 to 15 kWh of usable storage covers essential loads for about a day. Whole-home backup usually needs 25 kWh or more. Get a quote from a qualified installer before you buy, and confirm the battery and inverter are compatible with your existing solar system.