How to Vent a Range Hood Through a Roof: Ducting, Caps and Codes

Venting a range hood through the roof needs a short metal duct run and a properly flashed cap. This guide covers planning, duct sizing, steps, and code rules.

By Galactic News Editorial · Published 2026-11-21T16:47:16+00:00 · Updated 2026-11-21T16:47:16+00:00

How to vent a range hood through the roof with ducting and a roof cap

How to Vent a Range Hood Through a Roof: Ducting, Caps and Codes

Venting a range hood through the roof is the most direct route outdoors for many kitchens. The duct runs straight up from the hood, through the ceiling and attic, and out a roof cap. The job is doable for a careful homeowner, but the details matter. Short duct runs, metal ductwork, and a properly flashed roof cap decide whether the system works well and stays dry. This guide covers planning, duct sizing, installation steps, and the code rules to check first.

Plan the Route Before You Cut Anything

Start with the hood manual. It states the duct size and the mounting height. Broan manuals for common under-cabinet hoods call for mounting 18 to 24 inches above the cooking surface. That height balances smoke capture with headroom. Next, map the duct path. The best route is the shortest one with the fewest elbows. Every elbow adds resistance and cuts airflow. A straight vertical run through the roof is ideal for a single-story kitchen. For a multi-story home, the duct may run between ceiling joists or through a soffit before turning up. Check what sits above the kitchen. Roof framing, plumbing vents, and wiring can all block the path. Mark the duct centerline from inside the attic before you cut the ceiling. Confirm the route is clear of joists and rafters. If the path is blocked, shift the hood or choose a different route rather than cutting structural framing.

Duct Size and Material Choices

Use the duct size the hood maker specifies. Common sizes are 3-1/4 by 10 inch rectangular duct and 6, 7, or 8 inch round duct. Do not shrink the duct to fit a tight space. A smaller duct chokes airflow and raises noise. Use rigid metal duct only. Broan installation instructions are explicit: never use plastic duct, and never vent into an attic space. Grease buildup in an attic is a fire hazard. Metal duct contains a grease fire if one starts on the range. Tape every joint with foil duct tape so the run is airtight. A damper at the hood and a damper or backdraft flap at the cap stop cold air from flowing back into the kitchen. Check that the two dampers do not interfere with each other. Remove the hood damper flap if the manual says it conflicts with the cap damper.

How to Vent a Range Hood Through the Roof

Work from the outside in where you can. Broan manuals advise starting at the exterior and running the duct back to the hood. That keeps the alignment straight.

  1. Mark and cut the roof opening. Drill a pilot hole from inside the attic at the duct centerline. From the roof, mark a hole slightly larger than the duct. Broan roof cap instructions call for a hole about half an inch larger than the ductwork. Cut through the shingles and roof deck with a reciprocating or saber saw.
  2. Trim the shingles. Cut back the shingles around the opening so they fit snugly around the cap flashing. Lift the shingles above the opening. The top edge of the flashing slides underneath them.
  3. Run the duct up through the roof. Assemble the duct sections and tape all joints. Run the duct through the opening. Trim the duct parallel to the roof pitch. Leave a maximum of three quarters of an inch of duct projecting above the roof surface on the high side. Seal around the duct with roof cement.
  4. Install the roof cap. Slide the back edge of the cap flashing under the lifted shingles. Nail the flange to the roof deck at the top and sides, and directly to the roof at the bottom. Seal around the cap with roof cement. Seal every nail head and every shingle that was cut or lifted.
  5. Connect the duct to the hood. Run the duct down to the hood. Leave enough duct inside the room so it overlaps the hood damper connector by three quarters of an inch when the hood is installed. Tape the joint.
  6. Mount and test the hood. Mount the hood at the specified height. Connect the electrical supply. Run the fan on each speed. Check for air leaks at the joints and for backdraft when the fan is off. Confirm the cap damper opens freely and closes fully.

Roof Cap Choices Compared

The cap is the part that keeps rain out while letting air escape. Match it to your duct size and roof type. Broan roof caps accept up to 3-1/4 by 10 inch rectangular duct or 8 inch round duct. The 634M steel roof cap is made for 6 inch round duct, with a flashing base of about 18.75 by 14.25 inches. Smaller roof vent kits accept 3 or 4 inch round duct, but those sizes suit bath fans, not most range hoods. Check the bird screen before installing. It must be in place to keep birds and debris out of the duct. Some caps include a built-in damper. Others rely on the hood damper alone. Pick a cap rated for your duct size and confirm the flashing suits your roofing material. Do not install a standard roof cap on a flat roof unless the maker says it is rated for one.

Cap typeDuct sizeBest forNotes
Standard roof capUp to 3-1/4 x 10 in or 8 in roundMost range hoodsFlashing slides under shingles; seal with roof cement
Broan 634M steel cap6 in roundSmaller hoods and bath fans18.75 x 14.25 in flashing base; bird screen included
Roof vent kit3 or 4 in roundSmall fans onlyNot for most range hoods; never install on a flat roof

Codes and Safety Checks

Building codes treat range hood exhaust as a safety issue, not a cosmetic one. Ducted fans must always vent outdoors. Venting into an attic, soffit, or crawl space is not allowed. Grease collects in the duct and in the enclosed space, and it can fuel a fire. Only metal ductwork is acceptable. Local codes may add rules on duct size, cap height above the roof, and clearance from windows and vents. Some areas require a permit for a new roof penetration. Check with your local building department before cutting. If the roof is steep, wet, or high, hire a roofer for the exterior work. Falls from roofs cause serious injuries every year. A roofer can also confirm the flashing will not void a roofing warranty. After installation, inspect the cap and flashing once a year. Look for cracked sealant, lifted shingles, and a stuck damper.

Bottom Line

Venting a range hood through the roof works best with a short, straight, metal duct run and a cap matched to the duct size. Mount the hood 18 to 24 inches above the cooktop. Cut the roof hole about half an inch larger than the duct. Flash the cap under the shingles and seal every joint with roof cement. Never vent into the attic, and never use plastic duct. Check local codes before you cut, and hire a roofer for the exterior work if the roof is steep or high.