Solar Panels for Mobile Homes and Park Homes: Power Options, Site Rules and What to Ask

Solar panels work on park homes and mobile homes, but the site agreement, roof structure and planning rules decide the project first. Here is what to check.

By Galactic News Editorial · Published 2026-11-25T16:38:22+00:00 · Updated 2026-11-25T16:38:22+00:00

Solar panels for mobile homes and park homes with site rules and power options

Solar Panels for Mobile Homes and Park Homes: Power Options, Site Rules and What to Ask

Yes, you can put solar panels on a mobile home or a park home, and the technology is the same as on a house. What is different is everything around the panels: who owns the land, what your pitch agreement says, whether the roof can carry the weight, and how your electricity is supplied and billed. The site agreement decides the project before the engineering does. Ask the site owner first, get the answer in writing, and only then spend money on a survey or a quote.

Solar panels for mobile homes: park home or static caravan?

The first step is knowing which kind of home you have, because the rules are different. Both are legally caravans under the Caravan Sites Act, but they are built to different standards and used in different ways.

DetailStatic caravanPark home
Built toEN 1647 leisure standardBS 3632 residential standard
Intended useHolidays onlyPermanent, year-round residence
Legal protectionNone under the Mobile Homes ActProtected under the Mobile Homes Act 1983
Typical siteSeasonal holiday parkResidential park, open year-round
OwnershipYou own the caravan, pay site feesYou own the home, pay a pitch fee

If you are not sure which you have, check your site licence and your park agreement. A genuine residential park home site will say so, because residential status has to be licensed by the local council. Around 200,000 people live in UK park homes, and the distinction matters for VAT, export payments and your legal rights.

Site rules come first

Most park home occupancy agreements restrict alterations to the home and the pitch. Many require the site owner to give written consent before anything fixed is installed, and site rules often name solar panels, heat pumps and other green energy equipment directly. One published set of site rules, for Ebor Park in York, states that any alteration including solar panels is not permitted except with the prior written approval of the owner, who may inspect plans and drawings first.

Ask for the specific term, not just a yes or no. Ask which term of the agreement applies, and what the owner would consent to. A site owner may refuse a roof-fixed array and accept a free-standing one, and you will not discover that from a flat no. Get the consent in writing. Verbal permission from a site manager who later leaves is worth nothing when the site changes hands.

Your rights and obligations sit in the written agreement with the park owner, and you have 28 days to review it before signing. The agreement sets out your minimum legal rights, the rules, the charges and the services. Privately owned sites must hold a licence from the local council, and the licence will usually carry conditions on how many homes can be on the park, the services and amenities, and health and safety. Ask about the site licence too, because its conditions may bear on what can be placed on a pitch.

Can the roof carry the panels?

Park homes are built to be transported, so the roof structure is sized for that, not for carrying several hundred kilograms of glass and aluminium. Most residential park homes have lightweight roof constructions using timber frames covered with felt, metal or bonded roof coverings. Standard panels weigh roughly 15 to 20 kilograms each, plus mounting equipment, so a typical array adds real load to a structure that was never designed for it.

This is a case for a qualified structural engineer, not a standard survey. The industry installation standard MIS 3002 treats roof types not covered by standard methods as needing a structural engineer, and a park home roof falls squarely in that category. A reputable installer will say so. If an installer waves the question away, find another installer.

Power options for mobile and park homes

Solar for a caravan splits into two very different projects, and the right one depends on how the home is used.

Small portable off-grid kits suit static caravans used for holidays. Suitcase, foldable or fixed panel kits, typically 40 to 150 watts, charge a leisure battery for lights, phones and a small fridge. There is no planning question at all, because it is your own kit on your own caravan.

Roof-mounted grid-tied systems suit park homes used as a permanent residence. A typical array is 2 to 4 kilowatts peak, smaller than a house but the same technology. It needs an MCS-certified installer for any grant or export payment, and the G98 grid connection notification applies above certain sizes, just as it does for houses.

Plug-in and ground-mounted solar sits between the two and fits park homes well. It is reversible, with no roof penetration, which answers both the structural objection and the alterations objection in the site agreement. It still needs the site owner to agree, and the fire safety and grid notification considerations still apply, but it is often the easiest yes to get.

Money: VAT, export payments and costs

Solar installations on residential accommodation qualify for 0 percent VAT in the UK, the same relief a normal house gets. Park homes and static caravans used as someone's actual permanent home both qualify on the same terms as a house. A static caravan that is purely a holiday retreat on a seasonal leisure park almost certainly does not qualify, because it is not residential accommodation in HMRC terms. Get your installer to confirm the VAT rate in writing before you sign anything, referencing the GOV.UK VAT notice on energy-saving materials.

A grid-tied park home system can qualify for Smart Export Guarantee payments on the same terms as a house, but only with an MCS-certified installer. Establish how your electricity is supplied and billed before modelling any savings. Some parks resell electricity to residents, and that changes the numbers completely.

Costs vary with the roof, the array size and the site. One park operator puts a typical 6 to 8 panel park home installation at roughly 2 kilowatts, and suggests budgeting in the low thousands of pounds. Treat any figure as a starting point for quotes, not a price. Get at least two quotes from installers who have done park home work before, and ask for references from previous park home installations.

What to ask before you sign anything

  1. Site owner: which term of the pitch agreement applies, what would you consent to, and can I have it in writing?
  2. Site licence: does the licence or any planning condition restrict what can be placed on the pitch?
  3. Planning: ask the local planning authority directly how permitted development treats a park home. The rules permit solar on a dwellinghouse, and a park home is not obviously a dwellinghouse for these purposes, so do not accept a confident answer without knowing what it relies on.
  4. Structure: has a qualified structural engineer confirmed the roof can carry the array?
  5. Installer: are you MCS certified, have you installed on park homes before, and can I speak to a previous customer?
  6. Electricity: how is my electricity supplied and billed, and will the system qualify for export payments?
  7. VAT: confirm the VAT rate in writing, with the reference to the GOV.UK VAT notice.

Bottom line

Solar works on park homes and mobile homes, but the project is won or lost on paperwork, not panels. The site agreement comes first, the roof structure comes second, and the planning question needs a direct answer from the local authority. Get the owner's written consent, a structural engineer's view and an MCS-certified installer, and a park home can run on solar on the same terms as a house. Skip any of those steps and the panels may never go up, or may have to come down.